Alarming systems can connect to our Nx70 via the MQTT protocol.

This MQTT interface will be License and Password protected.

Since software 2.35, the MQTT interface is available for starting the first tests. It is not protected by a license but you need to enable it via auto-provisioning.


How to enable the application server web-page


You need to create the provisioning file below and start provisioning (Can be done via the web-interface)

Info
iconfalse
titleEnable MQTT web-page via provisioning

<?xml version="1.0" encoding="UTF-8"?>
<provisioning version="1.1" productID="e2">

<nvm>

<oper name="set_webui_visibility">

<param name="menu.settings/online-services/application-servers" value="visible" />

</oper>

</nvm>
</provisioning>


After the provisioning, the Application Servers page is now visible.

FAQ Nx70 - Application servers (Hidden)


Create an Application server

You now can create an application server access.

  • Id: id for external clients are: "as1", "as2" ...
  • Application server name (username) (At least one character is needed)
  • Password (has to be at least 32 characters using hexadecimal digits only: 0 1 2 3 4 5 6 7 8 9 a b c d e f A B C D E F)

FAQ Nx70 - Application servers (Hidden)


Info
iconfalse
titleAdd MQTT client via provisioning

<?xml version="1.0" encoding="UTF-8"?>
<provisioning version="1.1" productID="e2">

<nvm>

<oper name="set_external_client">

<param name="Username" value="as1" />
<param name="Password" value="123456789012345678901234567890ab" />

</oper>

</nvm>
</provisioning>

Panel
titleColor#F85404
titleBGColor#F0F0F0
titleExample

The following test

draw.io Diagram
bordertrue
diagramNameMQTT_Test
simpleViewerfalse
width
linksauto
tbstyletop
lboxtrue
diagramWidth561
revision1
environment is used.


Panel
titleColor#F85404
titleBGColor#F0F0F0
titleLocation service