ParameterBasic modeAlarm modePNG modeDescription
AutomaticOffOffOff

If enableddisabled:

Handset in/out of charger :

Basic mode: Monitoring is started, sensor test is no required.

Alarm/PNG mode: Logon procedure to the server is send.

Handset in charger:

Basic mode: Monitoring is disabled

has no influence on the monitoring mode.

If enabled, see flow chart belowAlarm/PNG mode: Logoff procedure to the server is send.

ManualOnOnOn

If enabled: User can manually logon/logoff

If disabled: Manual logon/logoff is not possible

Pause in chargerOffOffOff

If enableddisabled:

Handset in charger: 

Basic mode: Monitoring is paused.

Alarm/PNG mode: Server is informed that handset is in charger. Monitoring is disabled.

Handset out of charger:

Basic mode: Monitoring is started.

Alarm/PNG mode: Server is informed that handset is out of charger. Monitoring is started.

If disabled:

Handset in/out of charger has no influence on the monitoring mode.

/out of charger has no influence on the monitoring mode.

If enabled, see flow chart below.


Anchor
alarmpngautologon
alarmpngautologon
Alarm and PNG mode: Automatic logon enabled

draw.io Diagram
bordertrue
diagramNameAlarmPNGAutologin
simpleViewerfalse
width
linksauto
tbstyletop
lboxtrue
diagramWidth370
revision1


Anchor
alarmpngpauseincharger
alarmpngpauseincharger
Alarm and PNG mode: Pause in charger enabled

...