This White-paper describes the LAN synchronisation.

  1. LAN synchronisation
  2. Network requirements
  3. Distance between base stations
Background Color
color#F0F0F0

1. LAN synchronisation


If the DECT connection between base stations seems to be not reliable enough to permanently guarantee a stable DECT over the air synchronization, e.g., because they are separated by iron doors or a firewall, you can determine that synchronisation should take place via LAN. In this case you can switch to LAN synchronization where you also need to work with PTP master.


Advantage of LAN synchronization

  • No Synchronization levels needs to be configured.
  • When a base station fails (Not the LAN Master) it will not have any impact on the other base stations.
  • Fewer base stations required as the overlapping area of the base stations is smaller. The overlapping area for handset handover can be smaller, because neighbored base stations do not need to receive each other in stable error free quality, but they must still be able to detect each other for the process of dynamic channel selection.

Disadvantage of LAN synchronization

  • Base stations must be in the same network segment.
  • Precision Time Protocol (PTPv2), deviation must be lower then 500 ns (rms).
  • High reliable LAN network is needed, see below for the requirements.


Info

LAN synchronisation can look to be more easy then DECT synchronisation, but the Customers network has to be very reliable and network knowledge is required. Gigaset offers the possibility to measure the delay/quality but we can not advise you how to configure your switches as we are not the experts for these switches.

In case of bad network quality, it can take some seconds before the synchronization is lost. When this happens, all active calls of this base station are disconnected. It can take up to some minutes before synchronization is active again.


draw.io Diagram
bordertrue
diagramNameLANSynctwostep
simpleViewerfalse
width
linksauto
tbstyletop
lboxtrue
diagramWidth600
revision1

Background Color
color#F0F0F0

Anchor
LANsyncNetwork
LANsyncNetwork
2. Network requirements

Scroll to top


To be able to use LAN synchronisation, consider the following network requirements:


Precision Time Protocol (PTPv2), deviation must be lower then 500 ns (rms)



Base stations must be in the same network segment



The less switch hops. the lower the transmission delay and its jitter will be



The higher the bandwidth or quality of used switches is regarding packet delay and its jitter, the lower the packet delay and the lower the packet delay jitter will be.



Enhanced packet processing logics (like L3 switching or packet inspection) could have significant negative impact on the resulting packet delay jitter. If possible, they should be deactivated for the N870 base stations connected switch ports.



Significantly increased traffic load on a switch, in the range of the maximum throughput, could have significant negative impact on the packet delay jitter.



VLAN based prioritisation of LAN packets could be a fruitful measure to minimize packet delay and its jitter for N870 base stations.





Background Color
color#F0F0F0

Anchor
LANsyncDistance
LANsyncDistance
3. Distance between base stations

Scroll to top


DECT synchronisation

Distance between DECT base is measured with the SPK and should be -65 / -70 dBm


LAN synchronisation

The DECT base must be able to see the neighbor base via the DECT protocol.