title3. Second Authentication fails
Column
width50%

This functionality is available from Software 2.18.3 or higher.


  1. The client receives the WEB-server challenge and gathers the required credentials coming from the device configuration. A new request is send containing the username and hashed secret key.
  2. The WEB-server receives the request and requires an authentication. The WEB-server checks if the authentication information is in the request. The wrong authentication information is available. The WEB-server responds returning an 401 Unauthorized.
  3. On the Maxwell display, the user can add the Username and Password Manually.


    If you press "No" key then menu will be gone after 60 seconds.
    If you press "Any" key then 60 seconds timer will be set to 0 again, 60 seconds after pressing the last key, the menu will be gone.
    To start provisioning using these credentials, you need to press the "Save" key.
    You can try 3 times, will still fails, the menu will be gone. You need to reboot or press provisioning in web-interface to get menu again.
    If the entry is correct, the username and password is stored in the web-interface: