  • The base stations should be installed at least 1.8 meters above the ground.
  • To the ceiling a minimum distance of 50 centimeters should be kept.
  • The optimal installation height for a base is between 1.8 and 3m depending on the room height.
  • The distance to supply lines, cable ducts or metal cabinets should also be at least 50 centimeters.
  • The approved operating temperature of the base stations is between + 5 ° and + 45 ° Celsius.

To supply a hotspot, several base stations can be mounted side by side.

  • The minimum distance between stations depends on the environment. If there is direct visual contact, a distance of 5 to 10 m should be maintained. If walls or furniture affect the signal, a distance of 1 to 2m may be sufficient.