titleIntroduction

The following Licenses are available.

  • N870 Virtual Integrator software License
  • N870 DECT Manager license

The Integrator is available in 2 versions.

  1. N870 in Integrator only mode (Up to 4 DECT Managers)
    1. For each DECT manager an N870 DECT Manager license is needed
  2. N870 Virtual Integrator software (Up to 100 DECT managers)
    1. One N870 Virtual Integrator software license is needed
    2. For each DECT manager an N870 DECT Manager license is needed

The License is based on the N870 hardware MAC address.

How to add a License.

  1. Define the Master DECT Manager (Only when using the N870 Virtual Integrator software)
  2. Download the License Request file from the N870 License page
  3. Buy a License using the license Request file
  4. Upload the new License

Grace period.

You can use the system without any license for 35 days, after this:

  • All DECT handsets will show the message "Check License status"
  • License error message in the N870 web-interface
  • The system will stay functional.
  • After a factory reset, the system can be used again for 35 days without any license.

When you do not add a valid license then after additional 35 days:

  • The number of parallel calls will be set reduced to 1 call

Service.

If the license is not valid anymore due to:

  • Master DECT manager is broken and is replaced, therefore the license is not valid anymore.

You will have 35 days to request a new License file, see the grace period.


Info

Today, the license file procedure is a manual procedure. The online process is under development.

Panel
titleColor#F85404
titleBGColor#F0F0F0
titleMaster DECT manager
Section

Only needed when the Virtual Integrator is used.

As the license is based on the N870 MAC address and the Virtual Integrator is not an N870 device, you need to define the Master DECT manager.

In the Integrator web-interface go to SETTINGS - DECT manager - Administration - Global settings

Select the Master DECT Manager.

Info

The Master DECT manager need to be installed, connected and working as the real MAC address of this device is retrieved.

Panel
titleColor#F85404
titleBGColor#F0F0F0
titleDownload the License file

To request a new License, you first need to download the license file from the device.

The license file contains basic information about the system like:

  • Hardware information (MAC address of Master DECT manager)
  • Software version
  • Number of connected DECT managers / Base stations / handsets
  • Country selection
  • Data and time

The file content is encrypted.

In the Integrator web-interface go to SETTINGS - System - Licensing - Create Request File

Enter the number of additional DECT Managers you want to have.

The License request file is downloaded.

Panel
titleColor#F85404
titleBGColor#F0F0F0
titleBuy a License using the license file

To request a new license you need to add this file to your purchase order.

You will receive from Gigaset a License file.

Panel
titleColor#F85404
titleBGColor#F0F0F0
titleUpload the new License

In the Integrator web-interface go to SETTINGS - System - Licensing - Licence - Browse

Select the License file you received from Gigaset.

Click Upload

Your license is now enabled.