Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

PortaDial

doorintercom

Door Intercom


Tested with: Gigaset T300/T500 PRO: Software version 4.6.5.0
PortaDial type 1 with 1 pushbutton
PortaDial Interface 3 SIP

 



1. Create SIP account in Gigaset T300/T500

Go to: Configuration - Phones - Add additional Telephones



Use the settings like in the example above. Use the Password generator to create a secure Password


2. Open the Fasttel Wizard Elite door intercom web-interface

Go to Advanced Settings 1

SIP Server:  IP address of the Gigaset T300/T500  
Outbound Server:  IP address of the Gigaset T300/T500  
SIP User ID:  Telephone name defined in Gigaset T300/T500  
Authenticate ID:  Telephone name defined in Gigaset T300/T500  
Authenticate Password:  Password defined in Gigaset T300/T500  
Send DTMF:  Only activate the option via RTP(RFC2833)  

 

...