Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Section

Introduction

This page describes how to start the DECT registration window via auto-provisioning.

Web-page:

FAQ N870 - Auto provisioning Start DECT registration

Auto-provisioning


ParameterDescription
update_dmProcedure updating existing Dect Manager entry. Attribute of XML Oper, value is required as a parameter of updateDectManager operation.
Where value is treated as Identifier of the Dect Manager. (Name)
RegStartRegistration start time: must be typed as UNIX timestamp.
RegDurationTime period in seconds.
DMPpasswdDECT Manager Password

Example:

Start time 31-May-2018 14:59

Duration 300 seconds.

Password DECT manager: Gigaset

Info
iconfalse

<oper name="update_dm" value="local" >

<param name="RegStart" value="1527771540" />
<param name="RegDuration" value="300" />
<param name="DMPpasswd" value="Gigaset" />

</oper>

If the start-time time is in the past and the end-time (Start time + Duration) is not passed then the registration window is still open.

Info
titleImportant

Please add this code to the end of the Provisioning template, else you will get error message that provisioning failed.