Valid for:

N610

N670

N870

N870E

Embedded Integrator

Virtual Integrator

Panel
titleColor#F85404
titleBGColor#F0F0F0
titleIntroduction
Column
width60%
  • DECT manager redundancy needs working integrator:
    • Implementing backup DM without planning redundancy for integrator has limited value.
    • For DM redundancy it is recommended to plan redundancy for VI by the machine virtualization.
  • Disable the DECT Base on the Master DECT manager:
    • The backup DM and the DM redundancy feature can only provide redundancy for the DM role, but not for the local base functions!
    • Therefore you should not plan with the local base enabled on the DM, if you are planning for DM redundancy.

From software 2.47 DM redundancy for testing is implemented.

  • Needs virtual integrator (for integrator redundancy)
  • Master DECT manager must have DECT Base disabled
  • Add Back-up DECT manager, today via provisioning only
  • Failover will happen after approximate 10 minutes
  • No fallback to Master DM. Master will become back-up DM
  • Back-up DM does not need consume an additional DM license
  • Failover when:
    • Backup DM recognizes, that ( significant number majority of , all ) base stations are disconnected from master DM
    • Backup DM recognizes, that ( significant number majority of , all ) base stations are connectable to backup DM
      significant >= ( 60% + 1 of active base stations

    • this situation continuously lasts for more than 7 minutes this way preventing failover under regular software update duration (6 minutes).
Column
width40%

draw.io Diagram
bordertrue
diagramNameN870 Redundancy
simpleViewerfalse
width
linksauto
tbstyletop
lboxtrue
diagramWidth558
revision
3
4

Failover table
Number of active base-stations

Failover when n external*) active bases are detected

  • as not connecting to original DM
  • as connectable to backup DM

for more than 7 minutes.

. bases connect


*)Local base stations are never detected not connected to DM. 
Local base stations are never detected as connectable to backup DM.

11
22
32
43
54
64
75
85
96
107
117
128
138
149
1510
......
Panel
titleColor#F85404
titleBGColor#F0F0F0
titleAuto-provisioning
Info
iconfalse

<?xml version="1.0" encoding="UTF-8"?>
<provisioning version="1.1" productID="e2">
    <nvm>

    <oper name="add_backup_dm">
        <param name="DMPpasswd" value="Gigaset123+"/>
        <param name="DMDisplayName" value="dm2"/>
        <param name="DmBackupFor" value="dm1"/>
    </oper>

    </nvm>
</provisioning>

Panel
titleColor#F85404
titleBGColor#F0F0F0
titleWeb-interface
  • In the web-interface go to: SETTINGS - DECT Manager - Administrator
  • Click on the DECT manager where you want to configure the back-up DECT manager, the key Add backup DM will become functional

    Image Added
  • Click on the key Add backup DM
    Image Added
    And enter your settings
  • Then configure the Back-up DECT manager with the Integrator settings
    Image Added
  • The back-up manager is configured
    Image Added