titleIntroduction

From software 2.23, it is possible to DE-REGISTER the SIP account if the DECT handset is:

How long does it take before the system knows the handset is not available.

N670/N870(E)

  • Switched off
  • Out of range (Can take up to 3 hours for the system knows the handset is out of range)
  • Remove battery (Can take up to 3 hours for the system knows the handset switched off)

N610

  • 3 - 6 hours (DECT handset DETACH procedure is performed only for ARI-Class B systems  (N670/N870(E) but not for ARI Class A systems (N610))
Panel
titleColor#F85404
titleBGColor#F0F0F0
titleAuto-provisioning
Parameter
SipProvider.0.WithDeregOnHsNotReachable

0 = (Default) SIP account is not DE-REGISTERED

1 = REGISTER with Expires = 0 is send when the handset is out of range or switched off.

Example:

<param name="SipProvider.0.WithDeregOnHsNotReachable" value="1"/>

Panel
titleColor#F85404
titleBGColor#F0F0F0
titleWeb interface

In the web-interface go to: SETTINGS - Provider or PBX profiles - Deregister detached HS