Main features

 

  • Integrated AXIS colour video camera with illumination
  • Control of the 2 relays e.g. as door opener
  • Operation without Server possible
  • Complies with SIP standard for easy integration in SIP capable PBXes
  • Memory for pre-recorded audio (e.g. waiting information)
  • Front panel made from 3 mm thick V-2A steel
Vandal resistant SIP station with one call button, integrated AXIS colour video camera with illumination, viewing angle mechanically adjustable horizontally/vertically by 30°.

Power supply via PoE (IEEE 802.3af); IK 07 rating; video streams H.264 (MPEG-4 Part 10/AVC) and M-JPEG with max. resolution 1440 x 900 Pixel (1.3 MP); compatible to video components e.g. NVRs; support of video functions like motion detection, recording or detection of tampering attempts such as blocking or spray-painting.

 

source: http://www.commend.com/en/intercom/systems/intercom-terminals-vandal-resistant-stations-series-sip-ws-800v-200v-211v-da-200132/sip_ws_201v_ca.html

Datasheet SIP-WS2xx(CA)

PDF
nameDS-SIP-WS201VCA-EN-V20-0513.pdf

 

DS-SIP-WS201VCA-EN-V20-0513.pdf

Installation behind Tx00 (w/o auto provisioning)

Settings Tx00

  • Create a new phone "Standard Sip".
  • Set name and password
  • apply changes

 

Settings SIP-WS2xx(CA)

  • DHCP client is activated by default - if no DHCP server is available fallback settings will be set. IP 192.168.1.200
  • use webbrowser for configuration

 

Home Screen

The home screen is showing an overview of various informations.

e.g. Network settings and sIP information such as "Registration Status".

Image RemovedImage Added

 

Network Screen

Changes on the Network settings have to be confirmed by clicking "Apply".

SIP Screen

  • set Display Name
  • set User: same as set in Tx00 for phone
  • set Password: same as set in Tx00 for phone
  • set Proxy: IP-address of Tx00

There is the possibility to set up to two Fallback connections!

 

Changes on the SIP settings have to be confirmed by clicking "Apply".

Phonebook Screen

To establish an outgoing call a phonebook entry has to be added.

  • type in a name for the Contact
  • type in the caller-id (e.g. 101, in some cases you might have to add @domain to the caller-id)
  • assign a call button to the contact
    (If an input is activated, it could be choosen for call setup)

A phonebook can be imported as .csv.

Audio Screen

The sensitivity of the audio input (microphone) and the volume of the audio output (loudspeaker) can be adjusted.

Changes on these settings have to be confirmed by clicking "Apply".

 

 

 

 

 

 

 

 

 

 

Prerecorded audiofiles can be set for different actions on the module.

  • Outgoing Call (Button 0) --> playback at local loudspeaker
  • Outgoing Call (Button T) --> playback at local loudspeaker
  • Outgoing Call (Button X) --> playback at local loudspeaker
  • Incoming Call --> playback at local loudspeaker
  • Error --> playback at local loudspeaker
  • Location Message --> playback (once) at caller/called party

Input Screen

Here you can activate up to three inputs aon the module.

All inputs are using a common GND.

  • Standard Input can be configured as
    Break
    Make
  • x-Button Module are extension modules

Changes on these settings have to be confirmed by clicking "Apply".

Output Screen

Configure the two onboard outputs as

  • Door Opener
  • Attendend contact

 

Changes on these settings have to be confirmed by clicking "Apply".

 

System Settings

Here you can

  • do a firmware update
  • reboot the SIP station
  • export / import config files
  • change the login credentials for the WEB-UI
  • ...

The possibility to do SIP traces, SNMP setting and change language settings is available using the drop-down list.

 

Software Updates

For further information and Software updated check

www.commend.com/SIP

--> Downloads

Camera Settings

To use the axis camera of the SIP door station you have to active "anonymous viewer login", otherwise you have to configure the login credentials in the URL.

 

 

 

 

 

 

 

 

 

 

 

For using the axis camera with a DE700 / DE900 the resolution has to be changed, otherwise the display of the mjpg image is to slow.

 

For the usage of mjpg images you have to enter the follwoing URL to the DE 700 / DE 900

http://>ip-address>/mjpg/video.mjpg

 

The URL for usage of H.264 video (e.g. Maxwell):

rtsp://<ip-address>/axis-media/media.amp

(This link is not yet verified!)