  • The base stations should be installed at least 1.8 meters above the ground. 
Image Removed
  • To the ceiling a minimum distance of
50
  • 10 centimeters should be kept.
  • The optimal installation height for a base is between 1.8 and 3m depending on the room height.
  • We recommend installing all base stations at the same height.
  • The minimum distance between stations depends on the environment and if the base stations are synchronised.
    • Bases are slot synchronised (For example: 2 bases of the same N870 system that are synchronised)
      • Then a minimum distance of 30 cm should be maintained
    • Base are not synchronised
      • If 2 DECT base stations are not synchronized their slot-frames will drift over time. So, depending on their crystal frequency difference, one base will transmit in the receive frame of the other base station (and vice versa) after some time. This will block at least one or more slots on all frequencies and disturb the signal of the handsets. This effect is depending on the distance of the 2 bases. If there is direct visual contact, a distance of 5 to 10 m should be maintained. If walls or furniture affect the signal, a distance of 1 to 2m may be sufficient.
  • To supply a hotspot, several base stations can be mounted side by side.
  • The distance to supply lines, cable ducts or metal cabinets should also be at least
50
  • 10 centimeters.
  • The approved operating temperature of the base stations is between + 5 ° and + 45 ° Celsius.
We recommend installing all base stations at the same height.
  • Observer the safety distances and safety regulations. Observe the regulations specified in rooms where there is danger of explosions.

Image Added

Bases are synchronised, min 30 cm distance

Image Added

Base are not synchronised 

  • Do not install the base stations in Suspended ceilings, cup boards or other closed furnishings. The wireless coverage can be significantly reduced, depending on the materials used.
  • The
base stations should be installed vertically.The
  • location and alignment of the base stations installed should be identical to the position deemed optimum during the measurement stage.
  • If you need to install an DECT base against the ceiling, you can use an N870E. The external antenna's have to be rotated to the vertical position.

Image Added

  • The base stations should be installed vertically.
  • Avoid installations in the direct vicinity of cable channels, metal cupboards or other larger metal parts. These can reduce the radiation and couple into interfering signals. There should be a minimum distance of
50
  • 10 cm.
  • Observer the safety distances and safety regulations.Observe the regulations specified in rooms where there is danger of explosions.
  • To supply a hotspot, several base stations can be mounted side by side.

     We changed the distance from 50 cm to 10 cm.

    Image Added

    • The N610 can be put horizontal on a shelf, the maximum DECT signal strength will then be in the vertical direction which for houses having multiple floors could even be the best solution. If needed. the DECT range can be extended with repeaters. (N610 only)

    Image Added

    • The minimum distance between stations depends on the environment. If there is direct visual contact, a distance of 5 to 10 m should be maintained. If walls or furniture affect the signal, a distance of 1 to 2m may be sufficient.

    FAQ Nx70 - Base stations mounting instructions

    Image Removed

     We redefined the minimum distance of 0.1 m instead of 0.5 m