Introduction
This page describes how to start the DECT registration window via auto-provisioning.
Web-interface
Auto-provisioning
Parameter | Description |
---|---|
update_dm | Procedure updating existing Dect Manager entry. Attribute of XML Oper, value is required as a parameter of updateDectManager operation. If you do not know the name or would to address all DECT managers behind an Integrator you can use the @ Sign. |
RegStart | Registration start time: must be typed as UNIX timestamp. |
RegDuration | Time period in seconds. |
DMPpasswd | DECT Manager Password |
Example: Start time 31-May-2018 14:59 Duration 300 seconds. Password DECT manager: Gigaset If the start-time time is in the past and the end-time (Start time + Duration) is not passed then the registration window is still open. Important Please add this code to the end of the Provisioning template, else you will get error message that provisioning failed. |