IntroductionThe Gigaset T640 T440 offer the possibility to change the provisioning template of the Gigaset devices, that will offer you complete flexibility and customising the system conform your customer needs. ExampleOn the N510, the user would like to have the MWI for missed calls disabled. Web-interface setting N510Missed calls should be disabled. 
N510 Provisioning Parameter.First you need to find the provisioning parameter in the N510, this can be done using: Messaging - MWI Light |
---|
BS_AE_Subscriber.stMWI[N].bShowMissedCalls (N=0-5) | 0: No 1: Yes | Yes | WebUI:Settings - Messaging - MWI Light - Missed calls For each handset you can individually set on behalf of which type of new messages the LED should flash. The message types are: Missed calls, Missed alarms, eMail, Network Mailboxes. |
T640 T440 Provisioning ParameterIn the web-interface of the T640 T440 go to: Provisioning - Provisioning parameters - Create profile (N510)
- Select Phone Type (Gigaset N510 IP PRO)
- Add parameter (BS_AE_Subscriber.stMWI[0].bShowMissedCalls) and Value (0). (See below)
- Press Save

T640 T440 Provisioning groupsIn the web-interface of the T640 T440 go to: Provisioning - Provisioning groups - Create new group
- Add the created profile (N510)

Add Provisioning group to user.In the web-interface of the T640 T440 go to: User & extensions - Users and groups - Users - Edit the user setting
- Select the created Provisioning group.

The next time the device downloads the config, the new setting will be taken. |