Upload the software via the web-interface: The firmware is stored on the DECT manager and distributed to the base stations. In the web-interface go to: SETTINGS - System - Firmware
- Click Browse... and select the firmware file from your computer‘s file system.
- Click Upload to upload the firmware file.
- When ready, the pop-up "Press SET to start update schedule" will appear.
The URL to the firmware file will change to the local storage: http://localhost/swupdate/<firmwarefile> - Select Immediately if you want to start the update now.
- Scroll down and press SET
- The firmware update will start after a few minutes.
From software 2.32 or higher you see an icon if the firmware update is started.
You can downgrade to the previous version and keep your settings. If you downgrade to any other version, your device will be factory default |
Firmware update from an HTTP server If you do not have the file on your PC, you can also enter the URL of the firmware file that is stored on an external HTTP server. When the firmware update is started, all the devices will download the firmware from this external server.
Parameter | Description |
---|
Current version | Shows the current firmware version of the Integrator/DECT manager on which you are logged in. | Backup available for previous version | You can downgrade the firmware by installing any older version. When installing a new firmware the system automatically creates a data backup for the recent firmware. If you later downgrade to this version the data backup will be installed on the system. This way you have a downgrade to previous firmware version and data settings. Downgrade to any other version will reset the device to factory settings. | URL to firmware file | In the text field specify the URL of the configuration server where the firmware is located or click Browse... and select the firmware file from your computer‘s file system. | Planned schedule | At a specific date: Deselect the check box Immediately Enter the exact start time in the format: YYYY-MM-DD HH:mm Immediately: Select the check box next to Immediately (default) . . . the firmware update is started when you click on the Set button. | Confirmed schedule | Shows Immediately or the date for the next planned firmware update. |
|