Software 42.245, December 2017 Bug-fixes and improvements: - Broadsoft, every DECT handset can use there own phone-books.
- Broadsoft, default XSI URL can be changed if provider requires this.
- Bootloader, when firmware update is started, also User Agent is send.
- New search queries for SEARCH.CH
- XSI phone-books do not support special characters.
- Call lists improvement when number contains special characters.
- Repeater improvements.
- LDAP improvements.
|
Software 42.243, August 2017 Bug-fixes and improvements: - DHCP option 114 improvement
- Changing ptime from 20 ms to 30ms is now possible via provisioning
- DNS SRV is now working when platform returns an Error 500
- Random Call-ID for "message-waiting" subscribe after restart
- Correction for MWI subscribe 2nd handset is only sent one time
- Provisioning, DHCP option improvements
- Local storage of Spanish language
LDAP/Online Directories: - LDAP German characters are now shown correctly
- LDAP mobile device specific authentication problem fixed
- Reboot after LDAP request problem fixed
- Wrong display of Turkish characters in online directories fixed
Russia: - Support Provisioning Digest
- Cyrillic characters in XML phonebook are now shown correctly
|
Software 42.242, June 2017 Bug-fixes and improvements: - Broadsoft XSI Phonebooks
Turkish language/character set also in menus/directory contents Turkish translations updated Hungary: Call progress tone scheme added SIP UPDATE can be enabled/disabled in Web Configurator Unexpected call termination after n minutes because of SIP UPDATE - '501 Not Implemented Here' - fixed CLIP/COLP not updated via re-invite message - fixed Lack of speech-path when trying to transfer call - fixed Remove expired/not needed certificates Offer current cipher suites for successful TLS handshake HTTPS phone-book: certificate not loaded automatically - fixed by added TLS Support switch and web configurator setting - Device no longer goes to a loop when checking details of the first certificate
- SUOTA: Handset sends invalid SW version within SW version indication message fixed
- Web Configurator status page enhanced
- Uptime since last power interruption
- Details of registered handsets: product type, part-number, firmware version, connection status with check status button
- MTU negotiation (PMTUD) improved
- Blocking Register when router misses WAN link
- Send key does not work properly in "Next Call Anonymous"
Blocked number is no longer visible in redial list LDAP "Service not available" - fixed
|
Software 42.240, November 2016 Bug-fixes and improvements: - LDAP:
- autolookup problem solved / LDAP buffering
- character set problem fixed
- various problems fixed
- SUOTA problem fixed
- Base no longer resets while specific address is set in configuration file (URL)
- Occasional reboot after 'No entries found' popup fixed
- Innovaphone PBX registration problem solved
- Web configurator also in Turkish language
- Russia: CLIP problems fixed
- Russian/Czech translations corrected
- Nordic language special characters in display name improved
- "Configuration file (URL)" input field can be locked
- Caller ID update after call forwarding behind "Deutsche Telekom Digitalisierungsbox" problem solved
- Metaswitch: Configuration file URL length enhanced to 255 characters
- SIP Authentication name field length enhanced to 74 characters
- Broadsoft: Codec renegotiation optimized
- Broadsoft: No RTP after long 'on hold' state problem fixed
- Long names in name replacement improved
- Provisioning parameter problem solved
- Provisioning handset name truncation to 9 characters problem solved
- Secure provisioning via https is now also possible when XML has more than 200 lines/parameters
- In rare cases, handset did not terminate call when external subscriber hang up behind "Deutsche Telekom Speedport 724V"
- Online directory improvements
- DNS SRV:
- Auerswald 5000R PBX: One way audio problem fixed
|
Software 42.238, May 2016 Bug-fixes and improvements: Handset: Full support of new R650H PRO handset CLIP/COLP update after call transfer - Directories:
- Now Use LDAP address book also during active call (for transfer purposes).
- Refine search when using private phone-book fixed.
- Character set problems fixed with Gigaset T440/T640 PBX's
TR069: Various corrections, enhancements Secure provisioning error fixed - TLS:
- 23 new certificates added, also new root- and intermediate certificates from https://letsencrypt.org/certificates/
- Switch to select between TLS v1.0 and TLS v1.1
- Switch which to select which cipher suite is to be used:
- RSA_WITH_3DES_EDE_CBC_SHA
- RSA_WITH_RC4_128_MD5
- RSA_WITH_RC4_128_SHA
|
Software 42.231, December 2016 Bug-fixes and improvements: - New handset SL750H PRO has full compatibility
TLS: Optimization of the "Private Key Generation" procedure Optimized security by disabling IP dialling - Include MAC address in UA-header
XML phonebook - White/Yellow pages search field: 'City' now optional VOIP INVITE with send only not accepted by TELEKOM server Only 'All DECT' handsets option is available in 'Call Forwarding' list after registration to base station Exception occurred when handset was deregistered or when send connections were changed - It is not possible to set own area code number in case option 'Other Country' has been selected
- SIP/RTP port range configured in Web Configurator is not used in case of "Use random port mode = on"
- Bug in VoIP Wizard
- R630H PRO and SL610H PRO Call list is closed after few seconds
- Starface PBX manager is not working
- Unwished deleting of message waiting indicator with call lists
- Copy phone number from call list to directory is not always possible – phone comes back to Idle
- Wrong caller ID after call transfer
- TR-069: Change format of software version
- TR-069: Change ProductClass/Modelname
Handset name provisioning with special characters leads to incorrect result in WebUI. Special characters are not provisioned correctly. BS sends Busy signal to server, when 1 call is running on INT2 and another comes in for another SIP profile on INT1, when Call waiting is deactivated. If INT2 is in an external call, then no external connection to INT1 is possible. INT1 is busy. - SIP Session Timers according the RFC 4028: Session-refresh is now preferred via UPDATE, if supported by both peers
|
Software 42.210, February 2016 Bug-fixes and improvements: Known Issues: - Reboot occurs after de-registering handset
- Gigaset T300/T500 PBX: Handset name is not replaced after provisioning to Celsius server
- Copy phone number from call list to directory is not always possible – phone goes back to idle
- After firmware update system PIN is changed to default '0000'
|
Software 42.207, October 2014 Bug-fixes and improvements: - Added support in TR 069 for Device.DeviceInfo.ModelName and Device.DeviceInfo.HardwareVersion
Introduced hard-coded languages in WebUI for Germany, Polish, French, English (no need to download language package) Implement Periodic Inform over SSL Implement SW downgrade using TR069 Multiple access to WebUI using HTTP digest (as a User and Administrator) WebUI HTTP digest password is in sync with TR069 connection request password Sending HTTP digest auth retransmission in the same TCP streams - implemented 2-way authentication over SSL connection
- Multiple access to LDAP (only for N510)
TR069 Aligned translation for Eco Mode and Eco Mode + in WebUI to use new texts - Maximum Range and No Radiation - Display message "Provider registration failed"
- 2 to 3 seconds delay of begin of audio path after call pickup
|
Software 42.199, June 2014 Bug-fixes and improvements: - Corrected vCard Transfer via WebUI with special characters
- Minor bug fixes and improvements
- Timer change to 300s retry: phone fails in SIP Registration unable to be authenticated.
- No (dial)tone in certain call stages.
- When using TCP as transport protocol, the BS does not send BYE to the sip server.
|
Software 42.196, April 2014 Bug-fixes and improvements: - TR069 - option 43 implemented
- Fall Back to PSTN when SIP not available
- SIP USER ID in HTTP GET request
- If protocol settings in web-interface is on TCP but DNS answers with UDP, the web-interface settings are used.
- BROADSOFT: New parameter <I_PHONE_SYSTEM>
- BROADSOFT: CHECK-SYNC processing change
- BROADSOFT: HTTP digest
- BROADSOFT: Provisioning authentication
- BROADSOFT: <MAC_ADDRESS> processing change
- LDAP: Special character search
- LDAP: Use display format entry for name replacement, header and list of results of search
- LDAP: Create setting to switch name replacement on/off
- LDAP: 12. If 'now show' flag is set, do not show the tagged entry
- LDAP setup - Username field not long enough
- Email: SSL problem solved
- No dial/ringing tone in some call status behind some providers/platforms
- Device not visible in gigaset-config.com web-site
- Auto provisioning: Device doesn't get extended profile after factory reset.
- Initial SIP request might have wrong public port, authenticated repetition is correct
- Reboot possible when call forwarding at Broadsoft (Connect with Hold)
- Reboot after SIP account registration
- When using TCP as transport protocol, the BS does not send BYE to the sip server
- HOLD "to terminal" not working properly
- Base indicates "busy" when the caller terminates the call
|
Software 42.194, November 2013 Bug-fixes and improvements: - Improved handling of SIP notify messages (Call ID-changed) behind 3CX
- Device sends double DTMF tones.
|
Software 42.192, October 2013 Bug-fixes and improvements: Known Issues: - Double DTMF tones are send
|
Software 42.081, August 2013 Bug-fixes and improvements: - Access code special treatment in call-list for Nordic customer.
- DTMF control already at 180 ringing state and not only after 200 ok.
- Gigaset R630 support.
- Auto-provisioning update timer no reboot needed to activate.
- TR-069 - Zero Touch Activation
- Assign NTP server via DHCP
- Possibility to accept non trusted certificates automatically
- Instability of Base-station in some environments.
- Language problem (Czech language)
- Radio-buttons for Date & Time are on wrong position
- SIP call cannot be answered when is made 2s after the last one
- New Parameters do not take effect after provisioning using plain XML content
- Changing the timer interval from 24h-random to a fix time stops the regular check
- Text on Info Services settings page is missing
|
Software 42.078, June 2013 Bug-fixes and improvements: Access code special treatment in call-list for Nordic customer
The feature is by default disabled (not available in the WEBUI) It can be enabled via provisioning. Values which has to be adapted: Config Byte:
BS_CUSTOM.ucAkzVoipNotUsedNumberLength. Values: - 0x00 – feature available in WebUI but not working
- 0x01-0x09 – feature available in WebUI and working for numbers n-digits long and shorter
- 0xFF – feature disabled (not available in webUI) – the default one
Other values are not allowed
|
Software 42.076, January 2013 Bug-fixes and improvements: Gigaset PBX Manager supported by PRO handsets (SL610H PRO, S510H PRO). Feature control via handset menu: - Identity management / Hot Desking
- Calls lists
- DND
- Selection of CLIP number to be shown
- Group call settings
- Call divert
- Visual Voicemail
- Selective phone-book search for all available directories (also LDAP)
Enhancements: - Teles Interoperability: various improvements
- New Firmware/Profile Update: Do not alert user by MWI notification light any more for N510 IP PRO, N300 (A) IP
BugFixes: - tiPicall SoftSwitch interoperability: MWI for Voice Mail working again
- SMS: Problem with concatenation solved
- Broadsoft: Problem fixed with download of .xml file from server when digest username/password authentication is used
|
Software 42.075, December 2012 Bug-fixes and improvements: - Version 72 problem with very sporadically occurring instability and reset of base station after intense usage solved
- Problem with call transfer of an external party to an external target behind Cisco Manager solved
- De telefoongids (Netherlands): online phonebook search is working again
- Security:
- Password is masked in VOIP Wizard, no longer visible in clear text
- PIN entry delayed if user enters repeatedly wrong PIN
- S68H handset: CLIP presentation is working again
- Blind Call Transfer problem solved with Telavox.se and Firmix.at
- URI dialing: Problem with added international/local area codes fixed
- Problem with consultation call and "Use Area Code Numbers for Calls via VoIP" setting fixed
|
|