Valid for:

N610

N670

N870

N870E

Embedded Integrator

Virtual Integrator

Valid for N610 / N670 / N870 / N870E.

Via auto-provisioning it is possible to set an automatic reboot (version => 2.57.1).


Provisioning parameters
ParameterDescription
dm.<DM ID>.ScheduledRebootDays

<DM ID> possibilities

  • dm1 for DECT Manager 1
  • dm2 for DECT manager 2
  • dm... for DECT manager...
  • local
  • @ for all DECT managers 

We advise to use local and @ for small systems

Example: To reboot DECT manager 1
<param name="dm.dm1.ScheduledRebootDays" value="0,1,2,3,4,5,6"/>
Example: To reboot DECT manager 2
<param name="dm.dm2.ScheduledRebootDays" value="0,1,2,3,4,5,6"/>
Example: To reboot all DECT managers
<param name="dm.@.ScheduledRebootDays" value="0,1,2,3,4,5,6"/>

Example to disable automatic reboot for all DECT managers
<param name="dm.@.ScheduledRebootDays" value="never"/>
  • never = Off (default)
  • 0 = Sunday
  • 1 = Monday
  • 2 = Tuesday
  • 3 = Wednesday
  • 4 = Thursday
  • 5 = Friday
  • 6 = Saturday
dm.<DM ID>.ScheduledRebootTime<DM ID> possibilities see above
<param name="dm.dm1.ScheduledRebootTime" value="1:00"/>
  • Time = HH:MM (4:00 = default time)



Provisioning example enable or disable automatic reboot
<?xml version="1.0" encoding="UTF-8"?>
<provisioning version="1.1" productID="e2">



<nvm>

<!-- Default = never. Off = never, days of the week: 0=Sunday, 1=Monday, 2=Tuesday, 3=Wednesday, 4=Thursday, 5=Friday, 6=Saturday. value is , separated  -->
<!-- define the wanted DM (X) dm.X.Schedul… @ = all -->
<param name="dm.@.ScheduledRebootDays" value="never"/>
<!-- Default is 4:00. Time = HH:MM -->
<param name="dm.@.ScheduledRebootTime" value="12:38"/>

</nvm>
</provisioning>