Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Section
Panel
titleColor#F85404
titleBGColor#F0F0F0
titleIntroduction
Section

From software 2.26 the integrator only role is official released.

This role can be selected from the web-interface.

Go to: SETTINGS - System - Reboot and Reset - Reset to:

  • Integrator only - Dynamic IP
  • Integrator only - Keep IP

Image Modified

When the N870 has the role of Integrator, it can never be an Manager or Base station.

The N870 in role integrator only can handle:

  • Up to 4 DECT managers (N870)
  • Up to 240 DECT Base stations
  • Up to 800 handsets
  • Handover, Roaming and Load balancing is supported

Each DECT Manager can:

  • Up to 60 DECT Base stations
  • Up to 250 DECT handsets

Subscribers can

  • Accept or initiate calls in all DECT cells with there handset (Roaming)
  • Switch between the DECT cells during a call (Handover).
  • A handover is only possible if cells are synchronised.
Panel
titleColor#F85404
titleBGColor#F0F0F0
titleIntegrator role only

The N870 with the role integrator only allows you to use the N870 hardware to create an Large DECT multicell system with up to 4 DECT managers.

For each DECT manager you need to buy a license.

The configuration of the Integrator is the same like already described for the Virtual Integrator.

...