X2Com

Valid for T440/T640 Firmware version 1.1.3 or below

Feature                                                           
Outgoing CallsYes
Incoming CallsYes
CLIP incomingYes
CLIP outgoingYes
Call ForwardingYes
Call TransferYes
Call WaitingYes
DTMFYes
Anonymous CallYes
A-number forwardingYes

 

 

 

 

 

 

 

Important

X2Com uses multiple servers behind the domain name sip.x2c.nl (redundancy and load balancing), because of the possibility that a call can come in from another IP address than the registration IP, the call is declined if the other IP addresses are unknown to the PBX. To solve this you have to create dummy SIP-gateways.

 

Gigaset T640/T440 settings.

Gateway group:

In the Gigaset PBX go to "Administration" -> "Routes" -> "Gateway groups" - Enter the desired name and click on "Create new group":

SIP Gateway:

 

In the Gigaset PBX go to "Administration" -> "Routes" -> "SIP Gateways" - At "Gateway" enter the desired name and click on "Create new gateway":

Fill out the provider details:

 



Important

With the "Dial command" in above screenshot there is a need to dial an extra 0 for an outside line
If it is not wanted to select an outgoing line with an extra 0 the "Dial command" is as following: PJSIP/{prefix}{number}@[gateway}

Dummy SIP Gateways:

Underneath screenshots of the dummy accounts....

 

 

 

 

 

 

 

  • No labels