Introduction
This page describes how to start the DECT registration window via auto-provisioning.
Web-page:
FAQ N870 - Auto provisioning Start DECT registration
Auto-provisioning
Parameter | Description |
---|---|
update_dm | Procedure updating existing Dect Manager entry. Attribute of XML Oper, value is required as a parameter of updateDectManager operation. Where value is treated as Identifier of the Dect Manager. (Name) |
RegStart | Registration start time: must be typed as UNIX timestamp. |
RegDuration | Time period in seconds. |
DMPpasswd | DECT Manager Password |
Example: Start time 31-May-2018 14:59 Duration 300 seconds. Password DECT manager: Gigaset <oper name="update_dm" value="local" > <param name="RegStart" value="1527771540" /> </oper> |
If the start-time time is in the past and the end-time (Start time + Duration) is not passed then the registration window is still open.