You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Adding/Editing a synchronization reference

This page allows you to define which DECT device is responsible to synchronize a cluster managed by the DECT manager. You can edit an existing entry of the DECT manager synchronization table or add a new entry.

DM Name

  • For a new entry: Select a DECT manager from the option menu.

For an existing entry the identifier is shown.

Cluster

  • For a new entry: Select a cluster number of the selected DECT manager. Only one synchronisation reference can be set for a cluster.

For an existing entry: The cluster number of the selected DECT manager is shown.

Cluster external sync

  • Select the cluster‘s synchronisation reference:

Cluster external sync

  • Select the cluster‘s synchronisation reference:

No external sync Level 1 base of the cluster will only synchronise internally.
Best DECT base of DM Level 1 base of the cluster will synchronise with the best accessible
base station of the DECT manager. The DECT manager must be
selected from the Reference option menu.
Ext RFPI xxx Level 1 base of the cluster will synchronise with another DECT system.
Different RFPI matching levels are possible.
Ext RFPI (full match) All bits of the RFPI are considered, i.e., one
specific DECT system is referenced
Ext RFPI (-1 match)
Ext RFPI (-2 match)
. . .
-1 match: the last bit of the RFPI is ignored.
-2 match: the last two bits are ignored
. . .
The RFPI or a part of an RFPI must be entered in the Reference text
field. Matching base stations are used to synchronise.
LAN Master of DM Level 1 base of the cluster will synchronise with the LAN master of
the DECT manager. The DECT manager must be selected from the
Reference option menu.

  • No labels