Network requirements for Synchronization via DECT

To connect the N870 devices:

  • 100 Mbit/s switch port with corresponding cabling to the device is required. 
  • The switchport must allow multicast / broadcast messages. 
  • PoE IEEE 802.3af < 3.8 W (Class 1)

  • VLAN disconnection from other network devices: recommendation

  • Supports VLAN tagging

  • Activation of Quality of Service mechanisms: recommendation

  • DECT Manager and all base stations in the same layer 2 segment



Network requirements for Synchronization via LAN

To connect the N870 devices:

  • 100 Mbit/s switch port with corresponding cabling to the device is required. 
  • The switchport must allow multicast / broadcast messages. 
  • PoE IEEE 802.3af < 3.8 W (Class 1)

  • VLAN disconnection from other network devices: recommendation

  • Supports VLAN tagging

  • Activation of Quality of Service mechanisms: recommendation

  • DECT Manager and all base stations in the same layer 2 segment

Extra:



  • No labels