This DECT platform has one hardware, the device can have the following role. DECT Base (N870 & N670) - By default, the N870 is a DECT Base.
- By default, the N670/N610 has the role: Integrator + DECT Manager + DECT Base
- A DECT base has mini web-interface
- If the device is configured as DECT Manager, you can reset this device to Base via: Web-interface: Settings - System - Reboot and reset - Reset to Base only.
- Via the hard-key, see: FAQ - Installation
- Via the Power procedure, see: FAQ - Reboot and Reset to factory default
DECT Manager + DECT Base (N870 & N670) - Web-interface: Settings - System - Reboot and reset - Reset to DECT-Manager + Base - dynamic IP.
- Web-interface: Settings - System - Reboot and reset - Reset to DECT-Manager + Base - keep IP.
- Via the hard-key, see: FAQ - Installation
- Via the Power procedure, see: FAQ - Reboot and Reset to factory default
Integrator + DECT Manager + DECT Base (N870 & N670 & N610) Integrator + DECT Manager (N870 & N670) - Web-interface: Settings - DECT Manager - Administration - Edit DECT manager - change Capacity to Medium.
- Web-interface: Settings - Base stations - Administration - Edit Local Base-station - Activate base station to No.
DECT Manager (N870 & N670) - Configure the device as DECT Manager + DECT Base via the above procedure.
- Connect to the virtual integrator.
- Via the integrator switch of the DECT base:
When changing the device role the system is reset to factory setting. This means, that existing configuration and user data will be lost. If you change the role of a device that has been acting as Integrator, you should save the configuration previously |
|