The following alarms are supported by the handset:

  • Manual Alarm
  • Non Movement Alarm
  • Man Down Alarm
  • Time Alarm
  • Escape Alarm

General values are entered for all alarms. Furthermore, parameters are preconfigured for each alarm type, which can be adapted individually however for the corresponding application.


Use PNG Mode for BGR 139-compliant operation and observe the settings prescribed there.

At least one automatic alarm has to be activated here in addition to the manual alarm.

It is not possible to switch off all alarms in PNG Mode.


General Settings

These values are used in general for all alarm types within an operating mode. 

Procedure:

  1. Select the Additional Features icon in the main menu.
  2. Select Configuration.
  3. Enter the five-position service PIN and confirm with OK.
  4. Select one of the three operating modes.
  5. Select Alarms.
  6. Select General Settings.
  7. Change the values of the following parameters:


ParametersBasic modeAlarm modePNG mode
Alarm number(s) / Alarm DestinationAlarm Destination 1 <empty>--

Alarm Destination 2 <empty>--

Alarm Destination 3 <empty>--

LP Alarm Destination 1 <empty>--

LP Alarm Destination 2 <empty>--

LP Alarm Destination 3 <empty>--
Alarm repeat counter99--
Calling Time30 sec--
Audio ChannelHandsetHandsetHandset