The following alarms are supported by the handset:

  • Manual Alarm
  • Non Movement Alarm
  • Man Down Alarm
  • Time Alarm
  • Escape Alarm

General values are entered for all alarms. Furthermore, parameters are preconfigured for each alarm type, which can be adapted individually however for the corresponding application.


Use PNG Mode for BGR 139-compliant operation and observe the settings prescribed there.

At least one automatic alarm has to be activated here in addition to the manual alarm.

It is not possible to switch off all alarms in PNG Mode.


General Settings

These values are used in general for all alarm types within an operating mode. 

Procedure:

  1. Select the Additional Features icon in the main menu.
  2. Select Configuration.
  3. Enter the five-position service PIN and confirm with OK.
  4. Select one of the three operating modes.
  5. Select Alarms.
  6. Select General Settings.
  7. Change the values of the following parameters:


ParametersBasic modeAlarm modePNG mode
Alarm number(s) / Alarm DestinationAlarm Destination 1 <empty>--

Alarm Destination 2 <empty>--

Alarm Destination 3 <empty>--

LP Alarm Destination 1 <empty>--

LP Alarm Destination 2 <empty>--

LP Alarm Destination 3 <empty>--
Alarm repeat counter99--
Calling Time30 sec--
Audio ChannelHandsetHandsetHandset


Manual alarm

You can configure all settings here for the manual alarm, in other words for the alarm triggered with the red alarm key.

Depending on how the red alarm key is pressed (SP: Short press, LP: Long press), different alarms are signaled (Alarm/PNG) and different alarm destinations are dialed (Basic).

Procedure:

  1. Select the Additional Features icon in the main menu.
  2. Select Configuration.
  3. Enter the five-position service PIN and confirm with OK.
  4. Select one of the three operating modes.
  5. Select Alarms.
  6. Select Manual Alarm.
  7. Change the values of the following parameters:

ParametersBasic modeAlarm modePNG mode
Alarm Key


  • Short press
OnOnOn
  • Long press
OnOnOn
  • Multiple press
OffOffOff
Keypad LockedKey activeKey activeKey active
Delay

0 sec.

<10-900 sec>

0 sec.

<10-900 sec>

0 sec.

<10-90 sec>

Melody SP Alarm 5Alarm 5Alarm 5
Melody LPAlarm 6Alarm 6Alarm 6
Volume333
Some menus are missing


Non Movement Alarm

The Non Movement Alarm can be activated optionally. It is triggered if the sensors identify lack of movement over a defined configurable period of time.


The response time and the pre-alarm time cannot be added, rather the pre-alarm time has to be deducted from the response time. For example, a response time of 90 s and pre-alarm time of 15 s means that the pre-alarm will be triggered after 75 s and the alarm after 90 s.


Procedure:

  1. Select the Additional Features icon in the main menu.
  2. Select Configuration.
  3. Enter the five-position service PIN and confirm with OK.
  4. Select one of the three operating modes.
  5. Select Alarms.
  6. Select Non Movement Alarm.
  7. Change the values of the following parameters:


ParametersBasic modeAlarm modePNG mode
ActivationOnOnOn
Response Time

90 sec.

<10-900 sec>

90 sec.

<10-900 sec>

90 sec.

<10-90 sec>

Pre-alarm Time

15 sec.

<0-300 sec>

15 sec.

<0-300 sec>

15 sec.

<0-30 sec>

Sensitivity levelHighHighHigh


Man Down Alarm

The Man Down Alarm can be activated optionally. It is triggered if the sensors identify undue tilting of the handset over a defined configurable period of time (i.e. deviation from the vertical position).

Procedure:

  1. Select the Additional Features icon in the main menu.
  2. Select Configuration.
  3. Enter the five-position service PIN and confirm with OK.
  4. Select one of the three operating modes.
  5. Select Alarms.
  6. Select Man Down Alarm.
  7. Change the values of the following parameters:


ParametersBasic modeAlarm modePNG mode
ActivationOnOnOn
Response Time

90 sec.

<10-900 sec>

90 sec.

<10-900 sec>

90 sec.

<10-90 sec>

Pre-alarm Time

15 sec.

<0-300 sec>

15 sec.

<0-300 sec>

15 sec.

<0-30 sec>

Sensitivity levelHighHighHigh