Introduction.

The N870 has only one hardware, not like the N720 where a separate DECT manager and DECT base is available.

When you connect an N870 to the Power, it will start by default as a base station. You can change the role of the device using the following procedure.

 

Per default, the device is delivered as a base station.

To change the role to a DECT Manager or to reset the base, please follow this instruction.

  • To activate the programming mode, press and hold the hardkey for minimum 10 seconds.
  • After 10 seconds, the LED's will be switched off and the device is in the programming mode.
  • In programming mode you can step through the three options by single key presses.
  • The modes are indicated by the LEDs.
  • To activate the intended option: Press and hold the hardkey for 5 seconds (minimum 3 up to maximum 10 seconds).
  • The programming mode is closed after 20 sec of no activity.

Remark: Please be aware that existing configuration and user data will be lost. Please perform backup in advance if needed

 

Programming mode: 

Progr.
option
Role
IP
Reset to factory 
settings 
Password 
Web Configurator
Description
LED 1
LED 2
activate by
0    Programming modeoffoff 
1Base station yes Set role to base station (default). Greenpress & hold key for 5 seconds
2

Base station
DECT Manager + 
Integrator 

DHCP
IP adress obtained automatically 
yesadminSet role to Base + DECT Manager + Integrator.BlueBluepress & hold key for 5 seconds
3Base station
DECT Manager + 
Integrator 

Static IP: 192.168.143.1

Subnet mask: 255.255.0.0

yesadminSet role to Base + DECT Manager + Integrator and apply static IP adress. Bluepress & hold key for 5 seconds
  • No labels