This DECT platform has one hardware, the device can have the following role.

DECT Base (N870 & N670)

  • By default, the N870 is a DECT Base.
  • By default, the N670/N610 has the role: Integrator + DECT Manager + DECT Base
  • A DECT base has mini web-interface
  • If the device is configured as DECT Manager, you can reset this device to Base via: Web-interface: Settings - System - Reboot and reset - Reset to Base only.
  • Via the hard-key, see: FAQ - Installation
  • Via the Power procedure, see: FAQ - Reboot and Reset to factory default

DECT Manager + DECT Base (N870 & N670)

  • Web-interface: Settings - System - Reboot and reset - Reset to DECT-Manager + Base - dynamic IP.
  • Web-interface: Settings - System - Reboot and reset - Reset to DECT-Manager + Base - keep IP.
  • Via the hard-key, see: FAQ - Installation
  • Via the Power procedure, see: FAQ - Reboot and Reset to factory default

Integrator + DECT Manager + DECT Base (N870 & N670 & N610)

Integrator + DECT Manager (N870 & N670)

  • Web-interface: Settings - DECT Manager - Administration - Edit DECT manager - change Capacity to Medium.
  • Web-interface: Settings - Base stations - Administration - Edit Local Base-station - Activate base station to No.

DECT Manager (N870 & N670)

  • Configure the device as DECT Manager + DECT Base via the above procedure.
  • Connect to the virtual integrator.
  • Via the integrator switch of the DECT base:
    • Web-interface: Settings - DECT Manager - Administration - Edit DECT manager - change Capacity to Medium.
      Web-interface: Settings - Base stations - Administration - Edit Local Base-station - Activate base station to No.


When changing the device role the system is reset to factory setting. This means, that existing configuration and user data will be lost.

If you change the role of a device that has been acting as Integrator, you should save the configuration previously