Valid for:

N610

N670

N870

N870E

Embedded Integrator

Virtual Integrator

Valid for N610 / N670 / N870 / N870E. Software 2.53 or higher is needed.

From software 2.53 or higher it is possible to add the HTTP digest credentials via the Gigaset Redirect server.

If the customer provisioning server has an HTTP digest security implemented, it allows you to add the HTTP digest credentials via the redirect server so that zero touch provisioning is working.


Communication flow ein2 Gigaset Redirect server Customer provisioning server ein2 Gigaset Redirect server Customer provisioning server Connect to Gigaset redirect server 401 unauthorized Connect to Gigaset redirect server with: Username = MAC address and Password = stored in device Customer Provisioning server URL with http digest username and password Connect to Customer provisioning server 401 unauthorized Connect to Customer provisioning server with: Username = MAC address and Password = stored in device 401 unauthorized Connect to Customer provisioning server with: Username = http digest username and Password = http digest password Provisioning file If provisioning file download was successfulthen HTTP digest credentials are stored in thedevice and visible in the web-interface

Redirect server URL format = http(s)://<username>:<password>@URL


  • No labels