Scope

  • New: All settings of a DECT manager, including DECT registrations can be saved and uploaded to the same or another DECT manager.
  • Up to now restoring was only possible to the same device and did not include DECT handset registrations.
  • Use case: Quickly get system up and running again when a DECT manager is broken. Minimize downtime.No need to register handsets anew.
  • Web UI recommends to save settings after changes.
  • Caution: Do not operate original and cloned DECT manager in parallel. This will cause severe network troubles.

How to:

Save settings from old device

  1. DECT Manager firmware version needs to be equal or higher than 70.087.*.*.* in order to support clone feature
  2. Clone is also supported when saving settings from already cloned devices
  3. Saving settings is done by WebUI “Management -> Save and restore -> Save Device Settings to PC“

 

Clone settings to new device

  1. Firmware version of new device has to be equal or greater than device from which settings were saved
  2. If old device used permanent patches, it is required to apply these permanent patches to new device before cloning settings from old device
  3. Be sure that the old device is no longer used before proceeding
  4. Clone settings by WebUI “Management -> Save and Restore -> Restore Device Settings from PC”

 

Notes

  1. After reset to factory all settings (including clone information) are lost
  2. All kind of patches are still supported with cloned device (normal-, permanent- and wipeout-)

 