You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

Valid for:

N530

N610

N670

N770

N870

N870E

Embedded Integrator

Virtual Integrator

Introduction


Auto-provisioning
<?xml version="1.0" encoding="UTF-8"?>
<provisioning version="1.1" productID="e2">
<nvm>
 
    <!-- switch on SUOTA -->
    <param name="DmGlobal.0.SuotaEnable" value="1" />
 
    <!-- configure SUOTA package with the URL to the SUOTA binary -->
    <!-- URL always needs to be unique for each binary, e.g. Ein2 will not recognize if binary is replaced on the server without changing the path -->
    <param name="SuotaPackage.1.Url" value="profile.gigaset.net/device/suota/ch21/144_02.bin" />
 
    <!-- configure SUOTA window when SUOTA should be started (duration is given in minutes) -->
    <param name="SuotaWindow.1.Enabled" value="1" />
    <param name="SuotaWindow.1.Name" value="Window 1" />
    <param name="SuotaWindow.1.StartTime" value="13:20" />
    <param name="SuotaWindow.1.Duration" value="120" />
    <param name="SuotaWindow.1.DaysOfWeek" value="mon,tue,wed,thu,fri,sat,sun" />
 
    <!-- assign SUOTA window to the HS:
           0 -> SUOTA not allowed for the HS
           1 -> SUOTA window 1
           2 -> SUOTA window 2
           255- > only SUOTA pull is possible (currently default) -->
    <param name="hs.@.SuotaWindow" value="1" />
 
</nvm>
</provisioning>
Syslog output example
Update SUOTA software version 
Next opening of the SUOTA window 1 will be on 2025-09-26 13:20:00
SUOTA window 2 is not enabled
Next request in 151 seconds
wildcard write done
Download firmware version from: profile.gigaset.net/device/suota/ch21/144_02.bin
Update SUOTA software version 144.002.00
Syslog output example
Open SUOTA window: 1
Next request in 7200 seconds
Trigger SUOTA push notification in window 1
Trigger SUOTA push notification to HS 0
HTTP full download of the SUOTA software
HTTP	GET /device/suota/ch21/144_02.bin
HTTP	HTTP/1.1 200 OK 


After successful software update you will see:

Web-interface:

Syslog:

Syslog output example
SW version of HS 0 updated from 144.001.00 to 144.002.00





  • No labels